Job characteristics
one
High conversion efficiency and fast startup;
two
Good safety performance: The product has five protection functions: short circuit, overload, overvoltage/undervoltage, and over temperature;
three
Good physical performance: The product adopts an all aluminum shell, with good heat dissipation performance, hard oxidation treatment on the surface, good friction resistance, and can withstand certain external forces of compression or impact;
four
Strong load adaptability and stability.
work efficiency
The inverter itself also consumes a portion of electricity during operation, so its input power should be greater than its output power. The efficiency of an inverter is the ratio of its output power to input power, which means the inverter efficiency is the ratio of output power to input power. If an inverter inputs 100 watts of direct current and outputs 90 watts of alternating current, then its efficiency is 90%.
Type designation | SG125CX-P2 |
Input (DC) | |
Recommended max. PV input power | 175 kW |
Max. PV input voltage" | 100 v |
Min. PV input voltage/ Startup input voltage | 180V/200V |
Rated PV input voltage | 600V |
MPPT operating voltage range" | 180V-1000V |
No.of independent MPP inputs | 12 |
No.of PV strings per MPPT | 2 |
Max. PV input current | 360A(30A*12) |
Max. DC short-circuit current | 480A(40A*12) |
Max.current for DC connector | 30A |
Output (AC) | |
Rated AC output power | 125 kW |
Max.AC output apparent power | 125 kVA |
Max.AC output current | 181.1A |
Rated AC output current( at 230V) | 181.1 A |
Rated AC voltage | 3/N/PE,220V/380V;230V/400V |
AC voltage range | 320V-480V |
Rated grid frequency | 50 Hz/60 Hz |
Grid freguency range | 45 Hz-55 Hz/55 Hz-65 Hz |
Harmonic(THD) | <3%(at rated power) |
Power factor at rated power / Adjustable power factor | >0.99/0.8 leading-0.8 lagging |
Feed-in phases/AC connection | 3/3-PE |
Efficiency | |
Max.efficiency/ European efficiency | 98.5%/98.3% |
Protection & function | |
Grid monitoring | Yes |
DC reverse polarity protection | Yes |
AC short-circuit protection | Yes |
Leakage current protection | Yes |
Surge protection | DC Type1+I/AC Type I |
Ground fault monitoring | Yes |
DC switch | Yes |
PV string current monitoring | Yes |
Arc fault circuit interrupter (AFCI) | Yes |
PID recovery function | Yes |
Optimizer compatibility " | Optional |
General data | |
Dimensions(W*H*D) | 1020 mm*795 mm*360 mm |
Weight | 87 kg |
Mounting method | Wall-mounting bracket |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | <5W |
Corrosion | C5 |
Operating ambient temperature range | -30℃to60℃ |
Allowable relative humidity range (non-condensing) | 0%-100% |
Cooling method | Smart forced air cooling |
Max.operating altitude | 4000 m |
Display | LED,Bluetooth+APP |
Communication | RS485/WLAN (optional)/Ethernet (optional) |
DC connection type | Evo2(Max.6 mm²) |
AC connection type | OT/DTterminal(Max.240 mm²) |
AC cable specification | Outside diameter 30 mm-60 mm |
Grid compliance | IEC 62109-1,EN/IEC 61000-6-1/2/3/4,IEC 61727,IEC 62116,EN 50549-1/2,UTE C15-712-1,VDEV 0126-1-1, VDE-AR-N 4105:2018,VFR 2019,NC RfG,C99,UNE 217002,NTS,CE10-212019,CEIO-162019,NRS-097-2-1,IEC 63027 |
Job characteristics
one
High conversion efficiency and fast startup;
two
Good safety performance: The product has five protection functions: short circuit, overload, overvoltage/undervoltage, and over temperature;
three
Good physical performance: The product adopts an all aluminum shell, with good heat dissipation performance, hard oxidation treatment on the surface, good friction resistance, and can withstand certain external forces of compression or impact;
four
Strong load adaptability and stability.
work efficiency
The inverter itself also consumes a portion of electricity during operation, so its input power should be greater than its output power. The efficiency of an inverter is the ratio of its output power to input power, which means the inverter efficiency is the ratio of output power to input power. If an inverter inputs 100 watts of direct current and outputs 90 watts of alternating current, then its efficiency is 90%.
Type designation | SG125CX-P2 |
Input (DC) | |
Recommended max. PV input power | 175 kW |
Max. PV input voltage" | 100 v |
Min. PV input voltage/ Startup input voltage | 180V/200V |
Rated PV input voltage | 600V |
MPPT operating voltage range" | 180V-1000V |
No.of independent MPP inputs | 12 |
No.of PV strings per MPPT | 2 |
Max. PV input current | 360A(30A*12) |
Max. DC short-circuit current | 480A(40A*12) |
Max.current for DC connector | 30A |
Output (AC) | |
Rated AC output power | 125 kW |
Max.AC output apparent power | 125 kVA |
Max.AC output current | 181.1A |
Rated AC output current( at 230V) | 181.1 A |
Rated AC voltage | 3/N/PE,220V/380V;230V/400V |
AC voltage range | 320V-480V |
Rated grid frequency | 50 Hz/60 Hz |
Grid freguency range | 45 Hz-55 Hz/55 Hz-65 Hz |
Harmonic(THD) | <3%(at rated power) |
Power factor at rated power / Adjustable power factor | >0.99/0.8 leading-0.8 lagging |
Feed-in phases/AC connection | 3/3-PE |
Efficiency | |
Max.efficiency/ European efficiency | 98.5%/98.3% |
Protection & function | |
Grid monitoring | Yes |
DC reverse polarity protection | Yes |
AC short-circuit protection | Yes |
Leakage current protection | Yes |
Surge protection | DC Type1+I/AC Type I |
Ground fault monitoring | Yes |
DC switch | Yes |
PV string current monitoring | Yes |
Arc fault circuit interrupter (AFCI) | Yes |
PID recovery function | Yes |
Optimizer compatibility " | Optional |
General data | |
Dimensions(W*H*D) | 1020 mm*795 mm*360 mm |
Weight | 87 kg |
Mounting method | Wall-mounting bracket |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | <5W |
Corrosion | C5 |
Operating ambient temperature range | -30℃to60℃ |
Allowable relative humidity range (non-condensing) | 0%-100% |
Cooling method | Smart forced air cooling |
Max.operating altitude | 4000 m |
Display | LED,Bluetooth+APP |
Communication | RS485/WLAN (optional)/Ethernet (optional) |
DC connection type | Evo2(Max.6 mm²) |
AC connection type | OT/DTterminal(Max.240 mm²) |
AC cable specification | Outside diameter 30 mm-60 mm |
Grid compliance | IEC 62109-1,EN/IEC 61000-6-1/2/3/4,IEC 61727,IEC 62116,EN 50549-1/2,UTE C15-712-1,VDEV 0126-1-1, VDE-AR-N 4105:2018,VFR 2019,NC RfG,C99,UNE 217002,NTS,CE10-212019,CEIO-162019,NRS-097-2-1,IEC 63027 |