An inverter converts direct current (battery, battery) into alternating current (usually 220v50HZ sine or square wave). Simply put, an inverter is a device that converts direct current (DC) into alternating current (AC). It consists of an inverter bridge, control logic, and filtering circuit.
Simply put, an inverter is an electronic device that converts low voltage (12, 24, or 48 volts) direct current into 220 volts alternating current. Because it is usually used to convert 220 volts of alternating current into direct current, while the function of the inverter is the opposite, it is named after it. In a mobile era, mobile office, mobile communication, mobile leisure and entertainment. In a mobile state, not only does it require low-voltage direct current supplied by batteries or batteries, but it also requires indispensable 220 volt alternating current in daily environments, which can be met by inverters.
Input (DC) | |
Recommended max. PV input power | 35 kWp 42 kWp 46.2 kWp |
Max. PV input voltage* | 1100V |
Min. PV input voltage / Startup input voltage | 160V/200V |
Rated PV input voltage | 600V |
MPPT operating voltage range" | 160V-1000V |
No. of independent MPP inputs | 3 |
No.of PV strings per MPPT | 2 |
Max.PV input current | 90 A(30A*3) |
Max. DC short-circuit current | 120 A(40A*3) |
Max. current for DC connector | 30A |
Output (AC) | |
Rated AC output power | 25 kW 30 kW 33 kW |
Max.AC output apparent power | 27.5 kVA 33 kVA*** 36.3 kVA |
Max.AC output current | 41.8 A 50.2A 55.2A |
Rated AC output current( at 230N) | 36.2 A 43.5A 47.8 A |
Rated AC voltage | 3/N/PE,220/380V,230/400V |
AC yoltage range | 312V-480V |
Rated grid frequency | 50 Hz/60 Hz |
Grid frequency range | 45 Hz-55 Hz/55 Hz-65 Hz |
Harmonic(THD) | <3%(at rated power) |
Power factor at rated power / Adjustable power factor | >0.99/0.8 leading-0.8 lagging |
Feed-in phases/AC connection | 3/3-N-PE |
Efficiency | |
Max.efficiency /European efficiency | 98.4%/98.2% 98.5%/98.3% 98.5%/98.3% |
Protection | |
Grid monitoring | Yes |
DC reverse polarity protection | Yes |
AC short-circuit protection | Yes |
Leakage current protection | Yes |
Surge protection | DC Type l+II/AC Type ⅡI |
Ground fault monitoring | Yes |
DC switch | Yes |
PV string current monitoring | Yes |
Arc fault circuit interrupter (AFCI) | Yes |
PID recovery function | Yes |
Optimizer compatibility*** | Optional |
General data | |
Dimensions(W*H*D) | 645 mm*575 mm*245 mm |
Weight | 38 kg |
Mounting method | Wall-mounting bracket |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | <5W |
Corrosion | C5 |
Operating ambient temperature range | -30℃to60℃ |
Allowable relative humidity range (non-condensing) | 0%-100% |
Cooling method | Smart forced air cooling |
Max.operating altitude | 4000 m |
Display | LED,Bluetooth+APP |
Communication | RS485/Optional:WLAN, Ethernet |
DC connection type | Evo2(Max.6 mm²) |
AC connection type | OT terminal(16 mm²-35 mm²) |
AC cable specification | Outside diameter 18 mm-38 mm |
Grid compliance | IEC 62109,IEC 61727,IEC 62116, VDE-AR-N 4105:2018,IEC 61000-6-3.EN 50549- 1,CEI0-212019,CEI0-162019,VDE 0126-1-1/AI VFR 2019,UTE C15-712-1:2013, UNE 206007-1/RD 1699,UNE 217002,C99,IEC 63027 |
Crid support | Qat night function, LVRT, HVRT,active & reactive power control and power ramp rate control |
An inverter converts direct current (battery, battery) into alternating current (usually 220v50HZ sine or square wave). Simply put, an inverter is a device that converts direct current (DC) into alternating current (AC). It consists of an inverter bridge, control logic, and filtering circuit.
Simply put, an inverter is an electronic device that converts low voltage (12, 24, or 48 volts) direct current into 220 volts alternating current. Because it is usually used to convert 220 volts of alternating current into direct current, while the function of the inverter is the opposite, it is named after it. In a mobile era, mobile office, mobile communication, mobile leisure and entertainment. In a mobile state, not only does it require low-voltage direct current supplied by batteries or batteries, but it also requires indispensable 220 volt alternating current in daily environments, which can be met by inverters.
Input (DC) | |
Recommended max. PV input power | 35 kWp 42 kWp 46.2 kWp |
Max. PV input voltage* | 1100V |
Min. PV input voltage / Startup input voltage | 160V/200V |
Rated PV input voltage | 600V |
MPPT operating voltage range" | 160V-1000V |
No. of independent MPP inputs | 3 |
No.of PV strings per MPPT | 2 |
Max.PV input current | 90 A(30A*3) |
Max. DC short-circuit current | 120 A(40A*3) |
Max. current for DC connector | 30A |
Output (AC) | |
Rated AC output power | 25 kW 30 kW 33 kW |
Max.AC output apparent power | 27.5 kVA 33 kVA*** 36.3 kVA |
Max.AC output current | 41.8 A 50.2A 55.2A |
Rated AC output current( at 230N) | 36.2 A 43.5A 47.8 A |
Rated AC voltage | 3/N/PE,220/380V,230/400V |
AC yoltage range | 312V-480V |
Rated grid frequency | 50 Hz/60 Hz |
Grid frequency range | 45 Hz-55 Hz/55 Hz-65 Hz |
Harmonic(THD) | <3%(at rated power) |
Power factor at rated power / Adjustable power factor | >0.99/0.8 leading-0.8 lagging |
Feed-in phases/AC connection | 3/3-N-PE |
Efficiency | |
Max.efficiency /European efficiency | 98.4%/98.2% 98.5%/98.3% 98.5%/98.3% |
Protection | |
Grid monitoring | Yes |
DC reverse polarity protection | Yes |
AC short-circuit protection | Yes |
Leakage current protection | Yes |
Surge protection | DC Type l+II/AC Type ⅡI |
Ground fault monitoring | Yes |
DC switch | Yes |
PV string current monitoring | Yes |
Arc fault circuit interrupter (AFCI) | Yes |
PID recovery function | Yes |
Optimizer compatibility*** | Optional |
General data | |
Dimensions(W*H*D) | 645 mm*575 mm*245 mm |
Weight | 38 kg |
Mounting method | Wall-mounting bracket |
Topology | Transformerless |
Degree of protection | IP66 |
Night power consumption | <5W |
Corrosion | C5 |
Operating ambient temperature range | -30℃to60℃ |
Allowable relative humidity range (non-condensing) | 0%-100% |
Cooling method | Smart forced air cooling |
Max.operating altitude | 4000 m |
Display | LED,Bluetooth+APP |
Communication | RS485/Optional:WLAN, Ethernet |
DC connection type | Evo2(Max.6 mm²) |
AC connection type | OT terminal(16 mm²-35 mm²) |
AC cable specification | Outside diameter 18 mm-38 mm |
Grid compliance | IEC 62109,IEC 61727,IEC 62116, VDE-AR-N 4105:2018,IEC 61000-6-3.EN 50549- 1,CEI0-212019,CEI0-162019,VDE 0126-1-1/AI VFR 2019,UTE C15-712-1:2013, UNE 206007-1/RD 1699,UNE 217002,C99,IEC 63027 |
Crid support | Qat night function, LVRT, HVRT,active & reactive power control and power ramp rate control |